NEW DESIGN OF THE WELL KNOWN OGS 3.1 GAS SAMPLING
SYSTEM.
Omicron Gas Sampling System type OGS3.11 can be used in all spaces where gas
detection is requested. Our systems can handle several gasses simultaneously.
Omicron systems have the unique automatic ”blowback
feature”, which together with two sampling pumps create a rapid and
clean sampling cycle. Hence for Gas tankers we are able to handle
more points and still maintain the 30 minute rule of IMO Gas Code.
The system fulfils latest requirements from IACS, EC, IMO and all major classification societies’
rules and regulations.
THE FOLLOWING HIGHLIGHTS
ARE MENTIONED:
• New compact design
• Smaller cabinet
• Improved functions
• Upgraded software
• More maintenance friendly
OGS 3.11 is for permanent installation. Different models and options
cover most applications you will find onboard tankers. All Delivered
parts are completely assembled ready for interconnection to on site
application. The operator panel has LCD display
and individual LED lamps indicating each measuring point status.
Standard features:
• Infrared hydrocarbon sensor with range 0 - 100 % L.E.L.
• Low and high gas alarms.
• Flame arrestor and shut-off valve for each sampling tube.
• Automatic and sequential purging of each sampling tube.
• Manual disconnection of sampling points not in use (e.g. when water in
ballast tanks).
• Two vacuum pumps (main and sample).
• Non-return valves mounted on deck for ballast tanks in order to avoid
liquid entering into the system.
• Extensive hardware and software system monitoring.
Options:
• Repeater Display units. Up to 5 additional units with Master
control transfer function.
• Remote alarm unit. Simple alarm status panel with LEDs and
buzzer (e.g. for Bridge)
• Aux. relay outputs. Up to 32 relay outputs, freely configurable
to any sample point.
• Standby pump layout. This option will have extra set of pumps
with manual switch over.
• Multiple flow sensors (option). Main/bypass flow. Used for
special layouts (LNG etc.).
• Dual purge supply (E.g. Nitrogen and instrument air).
• Multi-gas analysing. Up to 3 different gas sensors can be
installed.
• Alarm printer.
• Bulkhead penetrations.
• Automatic disconnection of sample line when sample point
is manually disconnected
from scanning cycle.
• Single/Dual RS 485/422 ModBus RTU serial line output to
external computer.
• Custom made systems on request.
Specifications:
• Number of gas sampling points ....... Max. 48
• Purge air supply .............................. 7 bar
• Power supply .................................. 230V AC Nom. Max.
1200W
• Alarm for clogged tubes ................. Yes
• Calibration gas ............................... Included
• Serial line communication ............. RS 485/422 (RTU MODBUS)
• Sample/purge time range .............. 25 s - 9999 s