PRODUCT DETAILS FOR EACH SYSTEM


NOTE; We also provide portable gas warning equipment.

GAS DETECTION SYSTEM FOR BALLAST TANKS AND VOID SPACES
TYPE OGS 3.11 (NEW MODEL)

NEW DESIGN OF THE WELL KNOWN OGS 3.1 GAS SAMPLING SYSTEM.

Omicron Gas Sampling System type OGS3.11 can be used in all spaces where gas detection is requested. Our systems can handle several gasses simultaneously.
Omicron systems have the unique automatic ”blowback
feature”, which together with two sampling pumps create a rapid and clean sampling cycle. Hence for Gas tankers we are able to handle more points and still maintain the 30 minute rule of IMO Gas Code.

The system fulfils latest requirements from IACS, EC, IMO and all major classification societies’ rules and regulations.

THE FOLLOWING HIGHLIGHTS ARE MENTIONED:
• New compact design
• Smaller cabinet
• Improved functions
• Upgraded software
• More maintenance friendly

OGS 3.11 is for permanent installation. Different models and options cover most applications you will find onboard tankers. All Delivered parts are completely assembled ready for interconnection to on site application. The operator panel has LCD display and individual LED lamps indicating each measuring point status.

Standard features:
• Infrared hydrocarbon sensor with range 0 - 100 % L.E.L.
• Low and high gas alarms.
• Flame arrestor and shut-off valve for each sampling tube.
• Automatic and sequential purging of each sampling tube.
• Manual disconnection of sampling points not in use (e.g. when water in ballast tanks).
• Two vacuum pumps (main and sample).
• Non-return valves mounted on deck for ballast tanks in order to avoid liquid entering into the system.
• Extensive hardware and software system monitoring.

Options:
• Repeater Display units. Up to 5 additional units with Master control transfer function.
• Remote alarm unit. Simple alarm status panel with LEDs and buzzer (e.g. for Bridge)
• Aux. relay outputs. Up to 32 relay outputs, freely configurable to any sample point.
• Standby pump layout. This option will have extra set of pumps with manual switch over.
• Multiple flow sensors (option). Main/bypass flow. Used for special layouts (LNG etc.).
• Dual purge supply (E.g. Nitrogen and instrument air).
• Multi-gas analysing. Up to 3 different gas sensors can be installed.
• Alarm printer.
• Bulkhead penetrations.
• Automatic disconnection of sample line when sample point is manually disconnected from scanning cycle.
• Single/Dual RS 485/422 ModBus RTU serial line output to external computer.
• Custom made systems on request.

Specifications:
• Number of gas sampling points ....... Max. 48
• Purge air supply .............................. 7 bar
• Power supply .................................. 230V AC Nom. Max. 1200W
• Alarm for clogged tubes ................. Yes
• Calibration gas ............................... Included
• Serial line communication ............. RS 485/422 (RTU MODBUS)
• Sample/purge time range .............. 25 s - 9999 s



GAS DETECTION SYSTEM FOR ADVANCED SOLUTIONS IN FPSO, FSO, SPECIAL TANKERS AND OTHER SOPHISTICATED VESSELS
TYPE OGS 3.1

OGS 3.1 can be delivered in two basic versions; Split or Combined. In a Split version all mechanical and pneumatic components are mounted in a Detector Cabinet. Operator Panel is mounted in a separate cabinet, including power control components. It can also be mounted in an external console (these two versions will avoid noise from pneumatic components in control room on ships). In a Combined version the Operator Panel is mounted on the Detector Cabinet door. This version requires an additional Interface- and Power control cabinet. This version is prepared for compact installations and central instrument rooms on FPSO, FSO's etc.

The system fulfils latest requirements from IACS, EC, IMO and all major classification societies’ rules and regulations.

OMICRON Gas System OGS 3.1 is the 4th generation, fully computerised gas sampling system developed by OMICRON.

OGS 3.1 is for permanent installation. Different models and options cover most applications you will find onboard tankers. All Delivered parts are completely assembled ready for interconnection to on site application. OGS 3.1 is based on a scanning method, which means that sample points are being connected to a sensor in a cyclic sequence. The operator panel has LCD display and individual LED lamps indicating each measuring point status. To minimize scanning cycle time and guarantee fresh samples at all times, the system has two sample pumps. One main pump, taking samples from all sample points continuously and a smaller sample pump taking samples from the actual point according to the sequence. This secures quick response if gas is detected. Due to dual pump layout the system will continuously monitor all pneumatic components in the cabinet against malfunction. All types of malfunctions including leakage will be detected and alarmed. Automatic purging of sample line immediately after each sampling is finished.

Standard features:
• Infrared hydrocarbon sensor with range 0 - 100 % L.E.L.
• Low and high gas level alarms.
• Flame arrestor and shut-off valve for each sampling tube.
• Automatic and sequential purging of each sampling tube.
• Semi-automatic test facility for zero and span.
• Manual disconnecting of sampling points not in use (e.g. when water in ballast tanks).
• Two sampling pumps (main and sample).
• Non-return valves in ballast tanks in order to avoid liquid entering into the system.
• Extensive hardware and software system monitoring.

Options:
• Repeater Display units. Up to 5 addition units with Master control transfer function.
• Remote alarm unit. Simple alarm status panel with LEDs and buzzer (e.g. for Bridge)
• Aux. relay outputs. Up to 32 relay outputs, freely configurable to any sample point.
• Standby pump layout. This option will have extra set of pumps with manual switch over.
• Multiple flow sensors (option). Main/bypass flow. Used for special layouts (LNG etc.).
• Dual purge supply (E.g. Nitrogen and instrument air).
• Multi-gas analysing. Up to 3 different gas sensors can be installed (any sensors can be used).
• Alarm printer.
• Bulkhead penetrations.
• Automatic disconnection of sample line when sample point is manually disconnected
from scanning cycle.
• RS 485/422 ModBus RTU serial line output to external computer.
• Custom made systems on request.

Specifications:
• Number of gas sampling points ....... Max. 48
• Purge air supply .............................. 7 bar
• Power supply .................................. 230V AC Nom. Max. 1200W
• Alarm for clogged tubes ................. Yes
• Calibration gas ............................... Included
• Serial line communication ............. RS 485/422 (RTU MODBUS)
• Sample/purge time range .............. 25 s - 9999 s




   